2303S
With inner and outer rings
Filler material: PILAFLON™
Spiral wound gasket with PTFE filler, that has been degreased so that oil does not react with combustion-supporting gases (oxygen, ozone, etc.).
PTFE and various metals
Operating temperature range: -200 to +260°C
Maximum operating pressure: 15.5 MPaG (Class 900)
Gasket factor (m value): 3
Minimum design seating stress (y value): 68.9N/mm2
Minimum seating stress (y value): 39.2N/mm2
White
Gaskets/Spiral wound gaskets